| A | B | C | D | E | F | G | H | |
|---|---|---|---|---|---|---|---|---|
| 8 | Highest detected concentration (mg/kg) | |||||||
| 9 | PCE | TCE | cis-DCE | trans-DCE | VC | |||
| 10 | Soil Samples | 321 | 10 | 13.2 | 0.248 | 0.9 | from Mark's Table 1 historical soil sampling results + Mark's table 4 results for residual soil | |
| 11 | RBCs | Lowest Applicable RBC | 940 | 46 | 620 | 4,500 | 3.9 | |
| 12 | Occupational DC | 940 | 46 | 2,000 | 9,200 | 3.9 | ||
| 13 | Construction Worker DC | 1,600 | 120 | 620 | 4,500 | 30 | ||
| 14 | Excavation Worker DC | 44,000 | 3,400 | 17,000 | 130,000 | 830 | ||
| 15 | Occupational Volatilization to Outdoor Air | - | 96 | - | - | 89 | ||
| 17 | Highest post-IRM concentration (ug/L) | |||||||
| 18 | PCE | TCE | cis-DCE | trans-DCE | VC | |||
| 19 | Groundwater Samples | 17,300 | 2,100 | 13,000 | 72.6 | 17,600 | from Mark's Table 2 direct-push groundwater sampling results and Table 5 monitoring well results | |
| 20 | RBCs | Lowest Applicable RBC | 5,400 | 430 | 24,000 | 14,000 | 1,200 | |
| 21 | Occupational Volatilization to Outdoor Air | - | 19,000 | - | 1,800,000 | 6,800 | ||
| 22 | Construction & Excavation Worker Groundwater in Excavation | 5,400 | 430 | 24,000 | 14,000 | 1,200 | ||
| 24 | Highest post-IRM concentration (ug/m3) when subslab vent system is operating | |||||||
| 25 | PCE | TCE | cis-DCE | trans-DCE | VC | |||
| 26 | Air Samples | 29 | 0.64 | 0.52 | - | 0.026 | from Mark's Table 3 air sampling results and IRM completion report | |
| 27 | RBC | Occupational Inhalation | 47 | 3.0 | - | 260 | 2.8 | |
| 29 | 1) RBCs dated June 7, 2012 | |||||||
| 30 | 2) PCE = perchlorethylene | |||||||
| 31 | 3) TCE = trichlorethylene | |||||||
| 32 | 4) DCE = dichlorethylene | |||||||
| 33 | 5) VC = vinyl chloride | |||||||
| 34 | 6) DC = RBC for soil ingestion, dermal contact, and inhalation | |||||||