From: Jennifer Cline
Sent: Thu Dec 18 16:50:42 2014
To: jon patrick; Erik Moorhouse; Jake Ehredt
Cc: Jonathan Patrick; Dan Huff; Phillip Bender; Mark Strandberg; J.W. Ring
Subject: RE: Consent Decree Meeting Questions
Importance: Normal
Hi Jon,
Are you planning to be in tomorrow? I would like everyone to stop by for a short meeting around 10 AM. I would like to chat briefly regarding Irrigation practices and documentation.
Erik – If Jon is not in will you and Erik please stop in around 10 AM. Please bring the CD disk of the final draft if you can locate this?
Thanks,
Jennifer Cline, P.E.
City of Molalla
Public Works Director
O: 503.759.0218
F: 503.829.3676
From: jon patrick [mailto:jonpatrick1@live.com]
Sent: Wednesday, December 17, 2014 7:08 PM
To: Jennifer Cline; Mark Strandberg; Phillip Bender; 'J.W. Ring'
Cc: 'Jonathan Patrick'; Dan Huff
Subject: RE: Consent Decree Meeting Questions
The final draft has all the appendices and is about a hundred pages long. This might be the same minus the appendices. That disk with the final draft is at the plant.
Sent via the Samsung Galaxy S® 5 ACTIVE™, an AT&T 4G LTE smartphone
-------- Original message --------
From: Jennifer Cline <jcline@cityofmolalla.com>
Date:12/17/2014 5:31 PM (GMT-08:00)
To: Mark Strandberg <MStrandberg@ringbenderlaw.com>, Phillip Bender <PBender@ringbenderlaw.com>, "'J.W. Ring'" <JWRing@ringbenderlaw.com>
Cc: 'Jonathan Patrick' <jpatrick@cityofmolalla.com>, jonpatrick1@live.com, Dan Huff <dhuff@cityofmolalla.com>
Subject: Consent Decree Meeting Questions
Hi –
This is what I found regarding the recycled water treatment levels. They are even lower than we expected. This is an selection taken from page 4 of the amended RWUP I found in our files. I will need to confirm this is the document DEQ has approved. Jon - can you confirm this is the correct document?
Recycled water for Class A sites (Coleman Ranch, the Cemetery, and the Nursery) must be monitored daily and must not exceed a median of 2.2 total coliform organisms per 100 mL based on the last 7 days of analyses and a limit of 23 total coliform organisms per 100 mL in any one sample. In addition, Class A recycled water must be filtered and the turbidity must not exceed an average of 2 NTUs in a 24-hour period, 5 NTUs more than 5 percent of the time, and 10 NTUs at any time. Turbidity monitoring must occur once every hour at a minimum.
Recycled water for Class B sites (Jorgensen site and the WWTP) must be monitored three times per week and must not exceed a median of 2.2 total coliform organisms per 100 mL based on the last 7 days of testing and a limit of 23 total coliform organisms per 100 mL in any one sample. Turbidity monitoring is not required for Class B recycled water.
Jennifer Cline, P.E.
City of Molalla
Public Works Director
O: 503.759.0218
F: 503.829.3676