From: Jennifer Cline

Sent: Wed Jul 15 11:29:00 2015

To: Jake Ehredt

Subject: FW: Molalla Force Main Repair

Importance: Normal

 

Looks like we may need to verify his information below.

I believe the as-builts has the load ratings that I can send him.

Jennifer Cline, P.E.

City of Molalla

Public Works Director

O: 503.759.0218

F: 503.829.3676

image "file:///C:

From: Rusty Pressnall [mailto:rustyp@hdfowler.com]

Sent: Wednesday, July 15, 2015 9:33 AM

To: 'Jennifer Cline'

Subject: RE: Molalla Force Main Repair

Hi Jennifer,

When your guys get the pipe between the 90 and the reducer exposed, we need to get an OD tape on both pipe sizes. I noticed the drawing says 24” DIPS which is fairly uncommon around here, usually we use IPS pipe.

24” DIPS is 25.80” OD, 24” IPS is 24.00” OD.

8” DIPS is 9.05” OD, 8” IPS is 8.625” OD.

It’s important to verify what the pipe OD’s are and what the pressure rating needs to be so we can have everything built correctly.

Thanks,

Rusty

 

Rusty Pressnall | Service Manager

HD Fowler Company | Bellevue Branch

Phone: (425) 748-5348

Fax: (425) 641-8885 | Cell: (425) 449-9701

From: Jennifer Cline [mailto:jcline@cityofmolalla.com]

Sent: Tuesday, July 14, 2015 10:28 AM

To: Rusty Pressnall

Subject: Molalla Force Main Repair