From: Jennifer Cline

Sent: Fri Oct 23 14:14:40 2015

To: 'psmall@pacnorthinvest.com'

Cc: Nicolas Lennartz

Subject: Approach Inspection Failed

Importance: Normal

Attachments: rd750.pdf;

 

Hi Phil,

Both driveways were failed due to apron slope (the 1’ slope at the front of the driveway entrance) exceeding 12%. Right now I am measuring apron slopes upto 22%. Please see attached Option M – Partially lowered Sidewalk on ODOT Standards Drawing RD750. The 12% is required so that lower vehicles do not scrape when pulling into the driveway.

To achieve the 12%, you can increased the slopes (or steepen) the sidewalk ramps up to ~8%. They are now about 5-6%. That will lower the elevation of the 4’ wide sidewalk across the driveway, thus reducing the apron slope.

Please let me know when the corrections have been made and I will be out within 24 hours to re-inspect.

Thank you,

Jennifer Cline, P.E. | Public Works Director

Licensed in OR, WA

City of Molalla

117 N Molalla Ave. | PO Box 248 * |Molalla, OR 97038

O: 503.759.0218 | F: 503.829.3676

image