From: Rusty Pressnall

Sent: Wed Jul 22 13:39:52 2015

To: 'Jennifer Cline'

Cc: 'Jake Ehredt'; Seth Ainslie

Subject: RE: Molalla Force Main Repair

Importance: Normal

 

Hi Jennifer,

The reducer will get to our fab shop today, hopefully they will be able to repair it and get it headed to our Vancouver branch tomorrow afternoon. We probably won’t end up seeing it in Vancouver until Monday or so.

Right now the problem is the 24” DIPS electrofusion coupler. We have one in our system I thought I could use but it turns out it’s getting installed this Friday. The closest I can find is in GA, I’ll see if we can get one sent here for arrival in Vancouver next Tuesday or so. As soon as we know for sure when we have all the pieces in hand I’ll let you know when we can be out to install.

Thanks,

Rusty

 

Rusty Pressnall | Service Manager

HD Fowler Company | Bellevue Branch

Phone: (425) 748-5348

Fax: (425) 641-8885 | Cell: (425) 449-9701

From: Rusty Pressnall

Sent: Friday, July 17, 2015 1:00 PM

To: 'Jennifer Cline'

Cc: 'Jake Ehredt'

Subject: RE: Molalla Force Main Repair

Hi again,

Seth is picking up a piece of 24” DIPS DR9 to repair the reducer on his way back to Vancouver from Molalla. If the timing works out perfectly he will be able to get them both headed to the fabricators tonight. I’ll let you know if they make it out tonight.

R

 

Rusty Pressnall | Service Manager

HD Fowler Company | Bellevue Branch

Phone: (425) 748-5348

Fax: (425) 641-8885 | Cell: (425) 449-9701

From: Rusty Pressnall

Sent: Friday, July 17, 2015 10:25 AM

To: 'Jennifer Cline'

Cc: Jake Ehredt

Subject: RE: Molalla Force Main Repair

Hi guys,

Remember when I said 24” DIPS isn’t real common around here? Our fab guys don’t have any in stock. On the bright side, I think I’ve found some on a job near Portland, my contact is checking to see if they can spare a couple feet. I should hear back from him by the end of the day. KEEP YOUR FINGERS CROSSED! J

That being said, I think getting it finished by Wednesday is a little optimistic.

R

 

Rusty Pressnall | Service Manager

HD Fowler Company | Bellevue Branch

Phone: (425) 748-5348

Fax: (425) 641-8885 | Cell: (425) 449-9701

From: Jennifer Cline [mailto:jcline@cityofmolalla.com]

Sent: Friday, July 17, 2015 9:18 AM

To: Rusty Pressnall

Cc: Jake Ehredt

Subject: Re: Molalla Force Main Repair

Hi Rusty,

Jake is going to give you a call. The line is currently shut down until the repairs can be made. If possible, we would like to be up and running by next Wednesday.

JC

 

Sent from my iPhone

 

On Jul 17, 2015, at 9:04 AM, Rusty Pressnall <rustyp@hdfowler.com> wrote:

Hi guys,

Our fab guys are saying that a new 24” DIPS x 8” DIPS reducer will be about 4 weeks out. Their suggestion is to cut off the existing one and have them repair it. Turnaround time would only be about 24 hours in their shop and cost at least $1000 less than a new reducer. Is the system designed so that would be possible?

R

 

Rusty Pressnall | Service Manager

HD Fowler Company | Bellevue Branch

Phone: (425) 748-5348

Fax: (425) 641-8885 | Cell: (425) 449-9701

From: Jake Ehredt [mailto:jehredt@cityofmolalla.com]

Sent: Thursday, July 16, 2015 11:38 AM

To: Rusty Pressnall

Cc: Jennifer Cline

Subject: RE: Molalla Force Main Repair

Rusty

That will be no problem if we need to move the 8in valve. If you are asking if we can remove the 8 in valve entirely the answer is no. I have to have that valve to isolate riser heads for our irrigation lines.

Jake Ehredt

City of Molalla

Asst. Wastewater Plant Operator

12424 S. Toliver rd

Molalla Or, 97038

Wwtp (503)829-5407

Cell 971-241-7547

From: Rusty Pressnall [mailto:rustyp@hdfowler.com]

Sent: Thursday, July 16, 2015 11:17 AM

To: 'Jennifer Cline'

Cc: Jake Ehredt; Jason Clifford

Subject: RE: Molalla Force Main Repair

Now that we know what we’re dealing with, I can call the fab guys and see how fast they can do it.

Looks like the HDPE in the ground is 8” DIPS and 24” DIPS PE3408 DR11 which has a pressure rating of 160 PSI. Industry standard for HDPE currently is PE4710 which has a DR11 pressure rating of 200 PSI. We can design the new reducer accordingly.

Can we remove the 8” valve if we need to? Based on the lay length of the 24” tee, the 24” coupler, the 24x8” reducer and the 8” valve we may want to plan on being able to move the valve down the 8” line a foot or so in case we don’t have enough room between the existing tee and the new reducer. The only extra parts we would need are an 8” DIPS electrofusion coupler and gaskets.

Let me know if you think this would work,

R

 

Rusty Pressnall | Service Manager

HD Fowler Company | Bellevue Branch

Phone: (425) 748-5348

Fax: (425) 641-8885 | Cell: (425) 449-9701

From: Jennifer Cline [mailto:jcline@cityofmolalla.com]

Sent: Thursday, July 16, 2015 11:11 AM

To: Rusty Pressnall

Cc: Jake Ehredt; Jason Clifford

Subject: RE: Molalla Force Main Repair

Hi Rusty,

Do you have a good idea when you can schedule the repair. It is becoming more of a urgent need to get the lines up and running again for irrigation.

Regards,

Jennifer Cline, P.E.

City of Molalla

Public Works Director

O: 503.759.0218

F: 503.829.3676

image

From: Jennifer Cline [mailto:jcline@cityofmolalla.com]

Sent: Thursday, July 16, 2015 10:57 AM

To: Rusty Pressnall

Cc: Jake Ehredt

Subject: RE: Molalla Force Main Repair

Hi Rusty,

I spoke with Jake this morning. He informed me that the pressure leaving the plant from the effluent pump station is 105 psi. With a 25% FOS that would be 131 psi. However, I think I found the info you’re looking for. See attached, and let me know?

Also here are the measurements Jake made in the field today:

· 25.95” OD

· 9.10” OD

· 1.03” – from 90-deg “T” to 8” flange on valve

If you have any more questions that Jake can answer for you in the field, please feel free to call him at 1-971-241-7547.

Thanks,

Jennifer Cline, P.E.

City of Molalla

Public Works Director

O: 503.759.0218

F: 503.829.3676

image

From: Rusty Pressnall [mailto:rustyp@hdfowler.com]

Sent: Thursday, July 16, 2015 9:21 AM

To: 'Jennifer Cline'

Cc: 'Jake Ehredt'

Subject: RE: Molalla Force Main Repair

Hi Jennifer,

I don’t see anything on the docs you sent that gives us a clue as to the design pressure. Can you talk to your engineering people and see what pressure rating they need? The two most common types of HDPE are DR17 (125 PSI) and DR11 (200 PSI) but depending on what pressure the system was designed for it could be from DR32.5 (63 PSI) to DR7.3 (317 PSI).

If you can find a print line on the pipe it would be helpful but it’s old enough it may be long gone. The only other thing we could do is to disassemble some part of the system to get the wall thickness of the HDPE and work the pressure rating out from there.

Let me know how I can help,

Rusty

 

Rusty Pressnall | Service Manager

HD Fowler Company | Bellevue Branch

Phone: (425) 748-5348

Fax: (425) 641-8885 | Cell: (425) 449-9701

From: Rusty Pressnall

Sent: Wednesday, July 15, 2015 6:30 PM

To: Jennifer Cline

Cc: Jake Ehredt

Subject: RE: Molalla Force Main Repair

Hi Jennifer,

I’ll take a look at the design data tomorrow when I get to the shop (too hard to see on my little screen at home).

Based on the new pics I’m guessing the tee and reducer were built as one unit at the fitting manufacturer and not put together in the field. We may not be able to blame the contractor. J

Based on the color of the backing ring on the 8”, I’m guessing it’s IPS instead of DIPS (IPS is usually red, DIPS is usually blue). We should still put an OD tape on it to confirm.

I’ll get back to you after I look at the docs you sent relating to the design pressure for my best guess.

Thanks,

Rusty

 

Rusty Pressnall | Service Manager

HD Fowler Company | Bellevue Branch

Phone: (425) 748-5348

Fax: (425) 641-8885 | Cell: (425) 449-9701

From: Jennifer Cline [mailto:jcline@cityofmolalla.com]

Sent: Wednesday, July 15, 2015 4:32 PM

To: Rusty Pressnall

Cc: Jake Ehredt

Subject: RE: Molalla Force Main Repair

Hi Rusty,

Jake is still working on getting the measurements from your email today. We should have those to you sometime tomorrow morning.

Also I have included the Design Data information. It appears the other pipe used for this line is C-905. I also am sending the contract provisions for the HDPE. I hope this will provide enough information to determine the needed pressure rating.

Regards,

Jennifer Cline, P.E.

City of Molalla

Public Works Director

O: 503.759.0218

F: 503.829.3676

image

From: Rusty Pressnall [mailto:rustyp@hdfowler.com]

Sent: Wednesday, July 15, 2015 9:33 AM

To: 'Jennifer Cline'

Subject: RE: Molalla Force Main Repair

Hi Jennifer,

When your guys get the pipe between the 90 and the reducer exposed, we need to get an OD tape on both pipe sizes. I noticed the drawing says 24” DIPS which is fairly uncommon around here, usually we use IPS pipe.

24” DIPS is 25.80” OD, 24” IPS is 24.00” OD.

8” DIPS is 9.05” OD, 8” IPS is 8.625” OD.

It’s important to verify what the pipe OD’s are and what the pressure rating needs to be so we can have everything built correctly.

Thanks,

Rusty

 

Rusty Pressnall | Service Manager

HD Fowler Company | Bellevue Branch

Phone: (425) 748-5348

Fax: (425) 641-8885 | Cell: (425) 449-9701

From: Jennifer Cline [mailto:jcline@cityofmolalla.com]

Sent: Tuesday, July 14, 2015 10:28 AM

To: Rusty Pressnall

Subject: Molalla Force Main Repair