Table 9 – 340-253-8090 Oregon Temporary Fuel Pathway Codes for Fuels with Indeterminate CIs | |||||
Fuel | Feedstock | Process Energy | FPC | CI (gCO2e/MJ) | |
Ethanol | Corn | Grid electricity, natural gas, and/or renewables | ORETH100T | 77.35 | |
Sorghum | Grid electricity, natural gas, and/or renewables | ORETH101T | 93.35 | ||
Sugarcane and Molasses | Bagasse and straw only, no grid electricity | ORETH102T | 57.09 | ||
Any starch or sugar feedstock | Any | ORETH103T | 100.39 | ||
Corn Stover, Wheat Straw, or Sugarcane Straw | As specified in OR-Greet 2.0 | ORETH104T | 41.05 | ||
Biodiesel | Any feedstock derived from animal fats, corn oil, or a waste stream | Grid electricity, natural gas, and/or renewables | ORBIOD200T | 47.30 | |
Any feedstock derived from plant oils except for Palm-derived oils | Grid electricity, natural gas, and/or renewables | ORBIOD201T | 65.03 | ||
Any feedstock | Any | ORBIOD202T | 102.07 | ||
Renewable Diesel | Any feedstock derived from animal fats, corn oil, or a waste stream | Grid electricity, natural gas, and/or renewables | ORRNWD300T | 39.26 | |
Any feedstock derived from plant oils except for Palm-derived oils | Grid electricity, natural gas, and/or renewables | ORRNWD301T | 56.55 | ||
Any feedstock | Any | ORRNWD302T | 102.07 | ||
Biomethane CNG | Landfill or Digester Gas | Grid electricity, natural gas, and/or renewables | ORCNG500T | 63.96 | |
Municipal Wastewater sludge, Food Waste, Green Waste, or Other Organic Waste | Grid electricity, natural gas, and/or parasitic load | ORCNG501T | 50 | ||
Biomethane LNG | Landfill or Digester Gas | Grid electricity, natural gas, and/or renewables | ORLNG501T | 80.44 | |
Municipal Wastewater sludge, Food Waste, Green Waste, or Other Organic Waste | Grid electricity, natural gas, and/or parasitic load | ORLNG502T | 65 | ||
Biomethane L-CNG | Landfill or Digester Gas | Grid electricity, natural gas, and/or renewables | ORLCNG502T | 84.65 | |
Municipal Wastewater sludge, Food Waste, Green Waste, or Other Organic Waste | Grid electricity, natural gas, and/or parasitic load | ORLCNG503T | 70 | ||
Biomethane CNG, LNG, L-CNG | Dairy Manure | Grid electricity, natural gas, and/or parasitic load | ORLCNG504T | -150 | |
Electricity | Coal, Natural Gas, Hydroelectric Dams, Wind Mills, etc. | Oregon average electricity mix | ORELEC600T | 135.00 | |
Any Gasoline Substitute Feedstock-Fuel Combination Not Included Above | Any | Any | ORSG800T | 100.39 | |
Any Diesel Substitute Feedstock-Fuel Combination Not Included Above | Any | Any | ORSD801T | 102.07 |