340-230-0520
Operating Limits
x= 1ni=1nX1, y= 1ni=1nY1 (Eq. 1)
Where:
X1 = the PM CPMS data points for the three runs constituting the performance test,
Y1 = the PM concentration value for the three runs constituting the performance test, and
n = the number of data points.
R= Y1X1-z (Eq. 2)
Where:
R = the relative mg/dscm per milliamp for the PM CPMS,
Y1 = the three run average mg/dscm PM concentration,
X1 = the three run average milliamp output from the PM CPMS, and
z = the milliamp equivalent of the instrument zero paragraph (9)(b)(A) of this rule.
Ol=z+0.75(L)R (Eq. 3)
Where:
Ol = the operating limit for the PM CPMS on a 30-day rolling average, in milliamps.
L = the source emission limit expressed in lb/Mmbtu,
z = the instrument zero in milliamps, determined from paragraph (9)(b)(A) of this rule, and
R = the relative mg/dscm per milliamp for the PM CPMS, from Equation 3.
Oh= 1ni=1nX1 (Eq. 4)
Where:
X1 = the PM CPMS data points for all runs i,
n = the number of data points, and
Oh = the site specific operating limit, in milliamps.
340-230-0524
Initial and Annual Performance Testing
Cadj = Cmeas (20.9 - 7)/(20.9 - %O2) (Eq. 5)
Where: Cadj = pollutant concentration adjusted to 7 percent oxygen;
Cmeas = pollutant concentration measured on a dry basis;
(20.9 - 7) = 20.9 percent oxygen - 7 percent oxygen (defined oxygen correction basis);
20.9 = oxygen concentration in air, percent; and
%O2 = oxygen concentration measured on a dry basis, percent.