Other Agency Grain Loading and Opacity Limits
AGENCY | EQUIPMENT | GRAIN LOADING | OPACITY |
SWCAA (Vancouver WA) | Old HFB | 0.07 gr/dscf | 15% |
New HFB | 0.01 gr/dscf | 10% | |
Benton Clean Air Agency (WA) | All | 0.1 gr/dscf | 20% |
Siskiyou County (CA) | Non combustion | 0.30 gr/dscf | Ringlemann No. 2 |
combustion | |||
North Coast Unified AQMD (CA) | General combustion | 0.20 gr/dscf | Ringlemann No. 2 |
Steam generating units | 0.10 gr/dscf | ||
Non combustion | 0.20 gr/dscf | ||
Modoc County APCD (CA) | Non combustion | 0.30 gr/dscf | Ringlemann No. 2 |
combustion | |||
Shasta County (CA)
| Combustion – post 7-1-86 | 0.10 gr/dscf | 40% or Ringlemann No. 2 |
Combustion – pre 7-1-86 | 0.15 gr/dscf | ||
<10μ in Size post 7-1-86 | 0.05 gr/dscf | ||
<10μ in Size pre 7-1-86 | 0.10 gr/dscf | ||
All other PM post 7-1-86 | 0.15 gr/dscf | ||
All other PM pre 7-1-86 | 0.15 gr/dscf | ||
Idaho DEQ | Fuel Burning Wood > 10 MMBtu/hr and > 10-1-79 | 0.080 gr/dscf | 20% |
Fuel Burning Wood < 10 MMBtu/hr or < 10-1-79 | 0.200 gr/dscf | ||
Alaska | Fuel burning | 0.05 gr/dscf except | 20% except |
0.15 < 11-1-82 & >20% woodwaste | 30% < 11-1-82 and >20% woodwaste | ||
Montana | 20% | ||
Colorado | • fuel burning equipment < 1x106 BTU/hr total heat input design capacity. • fuel burning equipment with designed heat inputs > 1x106 BTU per hour, but < 500x106 BTU per hour, the following equation will be used to determine the allowable particulate emission limitation. • fuel burning equipment of > 500x106 BTU per hour or more. | • 0.5 lbs. per 106 BTU heat input
• PE=0.5(FI)-0.26 Where: PE = Particulate Emission in Pounds per million BTU heat input. FI = Fuel Input in Million BTU per hour. • 0.1 lbs. per 106 BTU heat input | 20% |
Wyoming | 20% after effective date of rule (?) | ||
40% before effective date of rule (?) |